🔒 CLOSED BETA — Limited seats available

Protection engineering. Rethought from scratch.

GridSense brings professional-grade power systems calculations to your browser — IEC 60909 fault analysis, IEEE 1584 arc flash, TCC coordination, and PDF reports. No desktop install. No large upfront licence.

Request Beta Access
Free during beta · Full professional access · No credit card
Already have access? Sign in →
21kA
Fault current calc
IEC 60909
Standard compliant
210+
Verified test cases
₹2,499
Per user / month
app.gridsense.io/dashboard/project-001
Isc 3-phase
21.66 kA
415V MDB busbar
Peak Current
40.67 kA
IEC 60909 κ=1.88
Max Arc Flash
0.04 cal/cm²
PPE Category 0
Coordination
0/3
⚠ Miscoordinated
TCC — Time Current Characteristics
MAIN 630A SUB 250A FINAL 100A Isc
Device Health
MAIN
4%
SUB
14%
FINAL
28%
THERMAL
100%
⚠ MAIN thermal capacity at limit
IEC 60909 Short-Circuit
IEEE 1584 Arc Flash
IEC 60255 TCC Coordination
ANSI 50/51 Overcurrent
COMTRADE Export
Contact Wear Monitoring
IEC 61439 Panel Verification
Thermal Modelling
PDF Report Generation
IEC 60909 Short-Circuit
IEEE 1584 Arc Flash
IEC 60255 TCC Coordination
ANSI 50/51 Overcurrent
COMTRADE Export
Contact Wear Monitoring
IEC 61439 Panel Verification
Thermal Modelling
PDF Report Generation

Protection software is
stuck in 2005

The tools haven't changed. The prices have only gone up. There's a better way.

01
Enterprise-only pricing
Existing power systems software is priced for utilities with massive capex budgets. Independent consultants, panel builders, and small firms are priced out entirely.
02
Installed desktop software
Single-machine licences. No collaboration. No version history. A site visit means a laptop. Sharing a project means emailing proprietary file formats nobody else can open.
03
Black-box calculations
You get a number. You don't always know exactly which clause of which standard produced it. When a client questions the result, you're back to first principles with a spreadsheet.

Every calculation.
Every standard.
One platform.

From initial fault level study to final arc flash label — GridSense covers the full protection engineering workflow, backed by verified physics and cited standards.

IEC 60909 Fault Calculation
3-phase, 1-phase, and peak fault currents. Transformer and cable impedance from nameplate data. Every result cites the exact clause it came from.
IEC 60909
📈
TCC Coordination
Interactive log-log time-current curves. Grading margin analysis across every device pair. Flags miscoordinations and suggests settings adjustments automatically.
IEC 60255
🔥
Arc Flash Assessment
IEEE 1584-2018 incident energy calculation. PPE category, arc flash boundary, and working distance for every bus. Generates compliant arc flash labels ready to print.
IEEE 1584
🔋
Device Health Monitoring
Contact wear, thermal capacity, and cumulative I²t tracking for MCCBs and ACBs. Predicts remaining useful life and flags devices approaching end-of-service.
Predictive
🛡️
IED Protection Relay
Full ANSI 50/51/67/21/27/59/81/87 function set. Zone-selective interlocking, directional overcurrent, and distance protection. COMTRADE export for relay testing.
ANSI C37
📄
PDF Report Generation
Stamped engineering reports with one-line diagram, TCC curves, coordination summary, and arc flash labels. Ready to submit to clients and authorities having jurisdiction.
Client-ready

From nameplate to
report in minutes

1
Enter or upload device data
Type in nameplate values or upload a CSV. GridSense parses transformer ratings, cable sizes, and MCCB settings automatically.
2
Run the calculations
IEC 60909 fault levels, TCC grading, and IEEE 1584 arc flash all run in under 2 seconds. Fully transparent — every formula shown.
3
Review and optimise
Interactive TCC chart shows miscoordinations instantly. Adjust TMS and delay settings live and see the effect in real time.
4
Export and deliver
Download a PDF report, export COMTRADE files for relay testing, or share a live link with your client — no account needed on their end.
IEC 60909
Short-circuit currents
IEC 60255
Measuring relays
IEEE 1584
Arc flash hazard
IEC 60947
LV switchgear
ANSI C37
Protection relays
IEC 61850
Substation comms
IEC 61439
LV assemblies
IEC 60364
Electrical installations

Free during beta.
Affordable after.

Beta users get full Professional access for free. Paid plans activate post-beta — less than one day of engineering time per month.

Starter
2,499
per user / month
For individual engineers and freelancers running occasional protection studies.
  • 10 active projects
  • IEC 60909 fault analysis
  • IEEE 1584 arc flash (2018)
  • IEC 60255 relay coordination
  • Cable & busbar sizing
  • Stamped PDF report export
  • Email support
Start free trial
Enterprise
Custom
volume pricing available
For utilities, EPCs, and teams needing white-labelling, SSO, or dedicated support.
  • Everything in Professional
  • Team & org management
  • White-label / OEM option
  • SSO / SAML integration
  • On-premise deployment
  • Dedicated account manager
  • SLA & DPA included
Contact sales →

Annual billing: £29/mo billed monthly or billed annually for Starter. See full plan comparison →

Why engineers are
joining the beta

We're in active development with our first cohort of protection and electrical engineers. Real reviews coming after beta.

⏱️
"Relay coordination studies take 2 full days with our current tools. I want to see if this can change that."
— Reason cited by protection engineers on the waitlist
💷
"Enterprise power systems licences are completely out of reach for independent consultants and small firms."
— Reason cited by independent chartered engineers on the waitlist
📄
"I need calculation reports that cite the exact IEC/IEEE clause — for PI insurance and client sign-off."
— Reason cited by panel builders and consultancies on the waitlist

Beta tester? Your real-world feedback shapes every release.
Share what works, what breaks, and what we're missing — reply to your invite email or hit the Beta Feedback button in-app.

🔒 Closed Beta

Join the beta.
Get in free.

We're onboarding a select group of protection and electrical engineers before public launch. Beta access is completely free — full Professional tier, no credit card, no commitment.

Request Beta Access Talk to us →

Free beta access · Full Professional features · No credit card needed